SPECIFICATIONS

Rosemount Models 244EH and 244ER PC-Programmable Temperature Transmitters

SPECIFICATIONS

 

 

Old

 

 

 

 

 

 

 

New

BASEFFA(1) Intrinsically Safe Installation Entity Parameters:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Loop

Umax:in

 

30 V dc

 

 

 

30 V dc

 

 

 

Group II C

Imax:in

 

200 mA

 

 

 

200 mA

 

 

 

Wmax:in

 

1.0 W

 

 

 

1.0 W

 

0.67 W

Zones 0 and 1

 

 

T5 (– 40 Ta 40 °C)

 

T5 (– 60 Ta 40 °C)

• T6 (– 60 Ta 40 °C)

 

 

 

 

 

 

 

T4 (– 40 Ta 80 °C)

 

T4 (– 60 Ta 80 °C)

• T5 (– 60 Ta 50 °C)

 

Ceq

 

13.4 nF

 

 

 

10 nF

 

 

 

Sensor

Li

 

0 μH

 

 

 

0 μH

 

 

 

Uo

 

24.2 V dc

 

 

 

13.6 V dc

 

 

 

 

Io

 

33 mA

 

 

 

80 mA

 

 

 

 

Po

 

0.2 W

 

 

 

0.08 W

 

 

 

Cable Load

 

 

 

IIC

IIB

IIA

 

 

IIC

IIB

 

IIA

 

Co (μF)

 

 

0.2

0.6

1.6

 

 

0.7

5.1

 

18.5

 

Lo (mH)

 

 

31

93

248

 

 

5

23

 

48

Special Conditions for Safe Use: The apparatus must be installed such that its external terminals and

 

Special Conditions for Safe Use: The apparatus must be installed in an enclosure which

the communication pins are protected to at least IP20.

 

 

 

 

 

affords it a degree of protection of at least IP20. Non-metallic enclosures must have

 

 

 

 

 

 

 

 

 

a surface resistance of less than 1 GΩ, light alloy or zirconium enclosures must be

 

 

 

 

 

 

 

 

 

protected from impact and friction when installed.

CSA(2) Intrinsically Safe Installation Connection Parameters:

 

 

 

 

 

 

 

 

Class I

 

 

• 30 V or less, 330 ohms or more

 

T6 (– 50 Ta 40 °C)

 

• 30 V or less, 340 ohms or more

Div. 1

T5 (– 50 Ta 60 °C)

 

• 28 V or less, 300 ohms or more

 

T5 (– 50 Ta 60 °C)

 

• 28 V or less, 300 ohms or more

Groups A, B, C,

 

 

 

and D

 

 

• 25 V or less, 200 ohms or more

 

 

 

 

• 25 V or less, 240 ohms or more

 

 

 

 

 

 

 

 

 

 

• 22 V or less, 180 ohms or more

 

 

 

 

• 22 V or less, 190 ohms or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T4 (– 50 Ta 80 °C)

 

• 30 V or less, 330 ohms or more

 

 

 

 

 

 

 

 

 

 

 

• 28 V or less, 250 ohms or more

 

 

 

 

 

 

 

 

 

 

 

• 25 V or less, 240 ohms or more

 

 

 

 

 

 

 

 

 

 

 

• 22 V or less, 190 ohms or more

 

 

 

 

 

 

 

 

 

Class I

 

 

• 30 V or less, 150 ohms or more

 

T4 (– 50 Ta 80 °C)

 

• 30 V or less, 230 ohms or more

Div. 1

 

 

 

 

 

 

 

 

 

 

• 28 V or less, 200 ohms or more

Groups C and D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• 25 V or less, 160 ohms or more

 

 

 

 

 

 

 

 

 

 

 

Factory Mutual(3)

Intrinsically Safe Installation

Entity Parameters:

 

 

 

 

 

 

 

Power Loop

Vi

 

30 V dc

 

 

 

30 V dc

 

 

 

Class I, II, and III

Ii

 

250 mA

 

 

 

240 mA

 

 

 

Pi

 

1.0 W

 

 

 

1.0 W

 

0.67 W

Div. 1

 

 

T5 (– 50 Ta 60 °C)

 

T5 (– 50 Ta 40 °C)

T6 (– 50 Ta 40 °C)

Groups A, B, C, D,

 

 

 

E, F, and G

 

 

 

 

 

 

T4 (– 50 Ta 80 °C)

T5 (– 50 Ta 50 °C)

 

 

 

 

 

 

 

 

 

 

 

 

Ci

 

0.008 μF

 

 

 

0.010 μF

 

 

 

 

Li

 

0 μH

 

 

 

0 μH

 

 

 

Sensor

Vt

 

10.7 V dc

 

 

 

13.6 V dc

 

 

 

 

It

 

15.3 mA

 

 

 

22 mA

 

 

 

 

Po

 

0.04 W

 

 

 

0.11 W

 

 

 

 

Ca

 

2.23 μF

 

 

 

0.8 μF

 

 

 

 

La

 

140 mH

 

 

 

60.0 mH

 

 

 

(1)For more information see approval certificate, Old: Model 644H: 95C2010X, Model 244E: 95C2019X; New: Model 644H: BAS00ATEX1033X, Model 244E: BAS00ATEX1034X

(2)For more information see Rosemount drawing 00644-1040, Rev. B (old) and 00644-1064, Rev AB (new).

(3)For more information see Rosemount drawing 00644-1056, Rev. B (old) and 00644-0009, Rev AA (new)

C-4

Page 60
Image 60
Fisher 244ER, 244EH manual Specifications, BASEFFA1 Intrinsically Safe Installation Entity Parameters, Factory Mutual3