Installation instructions

9

Location requirements

 

 

The area in which the dryer is located must be

 

EN

 

 

kept clear and free from combustible materials,

 

 

gasoline and other flammable vapors and

 

 

liquids. A dryer produces combustible lint so the

 

 

area around the dryer must be cleaned regularly

Fig.3 Rear venting

 

to keep it free of lint.

 

 

 

This dryer can only be vented from the rear and must be exhausted to the outdoors.

Alcove or closet installation

WARNING!

When installing a dryer in a closet/alcove it must be exhausted to the outdoors. No other fuel burning appliance can be installed in the same closet or alcove.

The top opening area in the door must be a minimum of 48 square inches (3100 mm2) and the bottom opening area must have a minimum of 24 square inches (1550 mm2). These openings must never be obstructed (a louvred door with the minimum air opening is acceptable).

Minimum installation clearances are required but more clearance is recommended.

min 56 5/16” (1430 mm)

Fig.4 Minimum clearances

1” (25 mm) 1” (25 mm) 1” (25 mm)

min 2” (50 mm) min 3” (76 mm)

48 sq” (3100 mm2)

total ventation area 72 sq” (4650 mm2)

 

 

 

24 sq” (1550 mm2)

Fig.5 Minimum ventilation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 11
Image 11
Fisher & Paykel DE62T27C, DG62T27C installation instructions Installation instructions, Alcove or closet installation