Fisher & Paykel DE62T27C, DG62T27C Installation instructions, wire connections, on page

Models: DE62T27C

1 124
Download 124 pages 34.3 Kb
Page 29
Image 29
4-wire connections
2

Installation instructions

4-wire connections

27

Use approved 4-wire Power Supply Cord or a 4-wire Cable for Direct Wiring as described

EN

on page 24.

 

1Remove the terminal block cover plate.

2Insert the power supply cable with a UL listed strain relief through the hole provided in the cabinet near the terminal block. Do not tighten strain relief screw until wiring connections are complete. Note: a strain relief must be used.

strain relief clamp sections

strain relief screws

3Remove center terminal block screw. Fig.30 Inserting the power cord

4Remove appliance ground link by removing the ground connector screw (green screw).

3

4

Note: If the appliance is moved back to a 3-wire installation the ground link must be refitted.

Remove link

Fig.31 Removing screws

5Connect ground wire (green) of the power supply cord to the ground conductor green screw. Tighten screw.

6Connect the neutral wire (white) of the power supply cord to the center terminal screw of the terminal block. Tighten screw.

7Connect the red wire and black wire to the upper and lower terminal block screws marked with the letter L. Tighten screws.

on page 24.Manual background7

6 Manual background 5

Fig.32 Connecting wiring

Manual backgroundManual background 7

8Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer and secure cover with securing screw.

9Tighten Strain Relief screws.

8

9

 

Fig.33 Refitting terminal block and screws

Page 29
Image 29
Fisher & Paykel DE62T27C, DG62T27C installation instructions Installation instructions, wire connections, on page