Installation instructions
4-wire connections
27
Use approved | EN |
on page 24. |
|
1Remove the terminal block cover plate.
2Insert the power supply cable with a UL listed strain relief through the hole provided in the cabinet near the terminal block. Do not tighten strain relief screw until wiring connections are complete. Note: a strain relief must be used.
strain relief clamp sections
strain relief screws
3Remove center terminal block screw. Fig.30 Inserting the power cord
4Remove appliance ground link by removing the ground connector screw (green screw).
3
4
Note: If the appliance is moved back to a
Remove link | Fig.31 Removing screws |
5Connect ground wire (green) of the power supply cord to the ground conductor green screw. Tighten screw.
6Connect the neutral wire (white) of the power supply cord to the center terminal screw of the terminal block. Tighten screw.
7Connect the red wire and black wire to the upper and lower terminal block screws marked with the letter L. Tighten screws.
7
6 5
Fig.32 Connecting wiring
7
8Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer and secure cover with securing screw.
9Tighten Strain Relief screws.
8 | 9 |
|