Installation instructions
Maximum length of exhaust duct
Preferred 4” Hoods
15
EN
When you have a 4” (100 mm) Hood
|
| Maximum length of 4” diameter metal duct. |
| |||
|
|
|
|
|
| |
Number of 90˚ |
| Rigid | Thick Wall Flexible Metal | |||
elbows/bends |
| (fully extended) | ||||
|
|
| ||||
|
|
|
|
|
|
|
0 | 64 ft |
| 19.5 m | 36 ft |
| 10.9 m |
|
|
|
|
|
|
|
1 | 54 ft |
| 16.5 m | 31 ft |
| 9.4 m |
|
|
|
|
|
|
|
2 | 44 ft |
| 13.4 m | 27 ft |
| 8.2 m |
|
|
|
|
|
|
|
3 | 35 ft |
| 10.6 m | 25 ft |
| 7.6 m |
|
|
|
|
|
|
|
4 | 27 ft |
| 8.2 m | 23 ft |
| 7.0 m |
Acceptable 2 ½” Hood
When you have a 2 ½” (60 mm) Hood
|
| Maximum length of 4” diameter metal duct. |
| |||
|
|
|
|
|
| |
Number of 90˚ |
| Rigid | Thick Wall Flexible Metal | |||
elbows/bends |
| (fully extended) | ||||
|
|
| ||||
|
|
|
|
|
|
|
0 | 58 ft |
| 17.6 m | 28 ft |
| 8.5 m |
|
|
|
|
|
|
|
1 | 48 ft |
| 14.6 m | 23 ft |
| 7.0 m |
|
|
|
|
|
|
|
2 | 38 ft |
| 11.5 m | 19 ft |
| 5.7 m |
|
|
|
|
|
|
|
3 | 29 ft |
| 8.8 m | 17 ft |
| 5.1 m |
|
|
|
|
|
|
|
4 | 21 ft |
| 6.4 m | 15 ft |
| 4.5 m |
|
|
|
|
|
|
|
For exhaust systems not covered by the exhaust duct length charts (such as multiple unit
TOLL FREE 1 888 9 FNP USA (1 888 9 367 872).