Fisher & Paykel DG62T27C Installation instructions, Electrical connections electric models only

Models: DE62T27C

1 124
Download 124 pages 34.3 Kb
Page 26
Image 26
For 4-wire connections by power cords

24

Installation instructions

Electrical connections (electric models only)

For 4-wire connections by power cords

4-wire power supply cord must have four 10 AWG copper wires and match a 4-wire receptacle of NMEA Type14-30R. The fourth wire (ground conductor) must be identified by a green cover and the neutral wire by a white cover.

For 4-wire connections by direct wiring

¾” UL-listed strain relief

to disconnect box

10-gauge, 3-wire with ground wire (Romex)

4 ¼”

1” of wires stripped of insulation

NEUTRAL wire (white or center)

bare ground wire

Strip 4 ¼” of outer covering from end of cable. Strip insulation back 1”.

Shape ends of wire into a hook.

Fig.22 Wiring 4-wire connections
Page 26
Image 26
Fisher & Paykel DG62T27C Installation instructions, Electrical connections electric models only, Wiring 4-wire connections