Fisher & Paykel DG62T27C, DE62T27C Installation instructions, grounding wire

Models: DE62T27C

1 124
Download 124 pages 34.3 Kb
Page 28
Image 28
3-wire connections plus separate grounding connector

26

Installation instructions

3-wire connections plus separate grounding connector

For use where local codes do not permit grounding through the Neutral wire.

Use approved 3-wire Power Supply Cord or a 3-wire Cable for Direct Wiring as described on page 23. A separate 10AWG copper grounding wire is required.

1Remove the terminal block cover plate.

2Insert the power supply cable with a UL listed strain relief through the hole provided in the cabinet near the terminal block. Do not tighten strain relief screw until wiring connections are complete. Note: a strain relief must be used.

2

Fig.27 Inserting the power cord

strain relief clamp sections

strain relief screws

3Remove center terminal block screw.

4Remove appliance ground link by removing the ground connector screw (Green screw).

5Connect a separate copper ground wire (green with yellow stripe) using the ground connector screw (Green screw). Make sure a ring terminal is used when connecting the ground wire and that the wire is firmly secured to an adequate grounding path.

3

Note: If the appliance is

4moved back to a 3-wire

installation the ground link must be refitted.

Remove link

Fig.28 Connecting the wires

Note: If the appliance is 7

6 installation the ground link must be refitted.grounding wire 5

Manual backgroundManual background 7

6Connect the neutral wire (center) of the power supply cord to the center terminal screw of the

terminal block. Tighten screw.

7Connect the other wires to the upper and lower terminal block screws marked with the letter L.

Tighten screws.

8Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer and secure cover with securing screw.

9Tighten strain relief screws.

8Manual backgroundManual backgroundManual background 9

grounding wire Manual background

It is recommended that a qualified electrician determine that the ground path is adequate

Fig.29 Refitting terminal Manual background block and tightening screws

Page 28
Image 28
Fisher & Paykel DG62T27C Installation instructions, wire connections plus separate grounding connector, grounding wire