Table 19: Fabric network activity LEDs
Fabric network | Interface or connection |
activity LED |
|
|
|
2/1 | Fabric channel connection between fabric channel 1 and fabric |
| channel 2. This LED is lit if there are two |
| installed in the chassis to indicate fabric backplane communication |
| between them. |
|
|
3 to 13 | Fabric backplane connection to |
| 3 to 13. |
|
|
Front panel connectors
Table 20 lists and describes the
Table 20:
Connector | Type | Speed | Protocol | Description |
|
|
|
|
|
MGMT | 10/100/1000 | Ethernet | Copper gigabit connection to out of band | |
|
|
| management interface. | |
COM | 9600 bps | Serial connection to the command line | ||
|
| 8/N/1 | serial | interface. |
B1, B2 | 10/100/1000 | Ethernet | Copper gigabit connection to the base | |
|
|
| backplane channel. | |
BASE 10G | SFP+ | 10 Gbps | Ethernet | SFP+ 10 gigabit connection to the base |
|
|
|
| backplane channel. |
FABRIC | SFP+ | 10 Gbps | Ethernet | SFP+ 10 gigabit connection to the fabric |
10G, 14/F8, |
|
|
| backplane channel. |
F7, F6, F5, |
|
|
|
|
F4, F3, F2, |
|
|
|
|
F1 |
|
|
|
|
FortiSwitch-5003A configurations
You can operate the
Base and fabric gigabit switching within a chassis
Figure 24 shows a FortiGate-5050 chassis with a FortiSwitch-5003A board in slot 1 and two FortiGate-5001A boards in slots 3 and 4. In this configuration the FortiGate-5001A boards are using base channel 1 for HA heartbeat communication. The FortiGate-5001A boards use base1 as the HA heartbeat interface.
|
|
58 |