FortiGate-5050 front panel

FortiGate-5050 chassis

FortiGate-5050 front panel

Figure 7 shows the front of a FortiGate-5050 chassis. Two FortiSwitch-5003 boards are installed in slots 1 and 2. Three FortiGate-5001SX boards are installed in slots 3, 4, and 5.

The FortiGate-5050 primary Shelf Manager is also visible. The factory-installed shelf managers provide power distribution, cooling, alarms, shelf status, and a telco alarm interface for the FortiGate-5050 chassis.

Figure 7: FortiGate-5050 front panel with FortiGate-5001SX and FortiSwitch-5003 boards installed

FortiGate-5001SX

boards

slots 3, 4,

and 5

FortiSwitch-5003

boards

slots 1 and 2

5

CONSOLE

USB

1

2

3

4

5

6

7

8

 

PWR ACC

 

 

 

 

 

 

 

 

STA

IPM

 

 

 

 

 

 

 

 

 

 

 

4

CONSOLE

USB

1

2

3

4

5

6

7

8

 

PWR ACC

 

 

 

 

 

 

 

 

STA

IPM

 

 

 

 

 

 

 

 

 

 

 

3

CONSOLE

USB

1

2

3

4

5

6

7

8

 

PWR ACC

 

 

 

 

 

 

 

 

STA

IPM

 

 

 

 

 

 

 

 

 

 

 

2

MANAGEMENT

TE H O

SYSTEM

CONSOLE

SR 2 3 2

RZ E 0

RZ E 1

RZ E 2

E2 E1

14 15

12 13

10 11

8 9

6 7

4 5

2 3

0 1

ZRE

CLK OK

EXT INT FLT FLT

HOT SWAP

RESET

LEDMODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

1

MANAGEMENT

ET H O

SYSTEM

CONSOLE

RS 2 3 2

RZ E 0

RZ E 1

RZ E 2

E2 E1

14 15

12 13

10 11

8 9

6 7

4 5

2 3

0 1

ZRE

CLK OK

EXT INT FLT FLT

SWAPHOT

RESET

LED MODE

ShMC

 

Critical

 

 

Hot Swap

ShMC

2

 

Major

 

 

1

Alarm

Minor

 

 

Status

Alarm

Console

Ethernet

 

 

Reset

 

 

 

Hot-swappable cooling fan tray

Power LED

FortiGate-5050

ESD socket

Shelf Manager

 

Also visible on the front of the FortiGate-5050:

Electrostatic discharge (ESD) socket, used for connecting an ESD wrist or ankle band when working with the chassis.

The location of the hot swappable FortiGate-5050 cooling fan tray behind panel.

Power LED.

Caution: Do not operate the FortiGate-5050 chassis with open slots on the front panel. For optimum cooling performance and safety, the slots must contain a FortiGate-5000 series board or an air baffle slot filler. As well the removable power supply panel must be installed over the power connectors on the back of the chassis.

FortiGate-5050 back panel

Figure 8 shows the back panel of a FortiGate-5050 chassis. The back panel includes two redundant -48V to - 58V DC power input connectors labelled Input A and Input B. The power input connectors provide redundant DC power connections for the FortiGate-5050 chassis and distribute DC power to the fan tray and the FortiGate-5000 series boards installed in the FortiGate-5050 chassis. Each power input connector includes a 24 Amp circuit breaker that also functions as an on/off switch for the power input connector.

If you require redundant power you should connect both power input connectors to DC power. If redundant power is not required, you should connect power input connector A to DC power. When operating, the power input connectors are covered with clear protection plates.

FortiGate-5000 Series Introduction

2801-30000-83466-20090108http://docs.fortinet.com/ Feedback

Page 28
Image 28
Fortinet FortiGate-5000 manual FortiGate-5050 chassis