WARNING: Before Operating Your Unit

WARNING: Before Operating Your Unit

Make sure the wiring is adequate for your unit.

If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in Table 1.

DO NOT use an extension cord.

The cord provided will carry the proper amount of electrical power to the unit; an extension cord may not.

Make sure that the receptacle is compatible with the air conditioner cord plug provided.

This insures proper grounding. If you have a two prong receptacle you will need to have it replaced with a grounded receptacle by a certi¿ed electrician. The grounded receptacle should meet all national and local codes and ordinances. Under no circumstances should you remove the ground prong from the plug. You must use the three prong plug furnished with the air conditioner.

Test the power cord

All Friedrich room air conditioners are shipped from the factory with a Leakage Current Detection Interrupter (LCDI) equipped power cord. The LCDI device meets the UL and NEC requirements for cord connected air conditioners effective August 2004.

To test your power supply cord:

1.Plug power supply cord into a grounded 3 prong outlet.

2.Press RESET (See Figure 1).

3.Press TEST, listen for click; the RESET button trips and pops out.

4.Press and release RESET (Listen for click; RESET button latches and remains in). The power cord is ready for use.

Once plugged in, the unit will operate normally without the need to reset the LCDI device.

If the LCDI device fails to trip when tested or if the power supply cord is damaged, it must be replaced with a new power supply cord from the manufacturer. Contact our Technical Assistance Line at (800) 541-6645. To expedite service, please have your model number available.

NOTICE

Do not use the LCDI device as an ON/OFF switch.

Failure to adhere to this precaution may cause premature equipment malfunction.

Table 1.

 

CIRCUIT RATING

REQUIRED WALL

 

OR TIME DELAY

 

RECEPTACLE

MODEL

FUSE

 

 

 

 

 

AMP

VOLT

NEMA NO.

 

 

 

 

 

 

 

 

 

 

SQ05 ‡ SQ06

 

 

 

 

 

 

SQ08 ‡ SQ10

15

125

5-15P

 

 

 

 

 

 

EQ08

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTICEWARNING

Electrical Shock Hazard

Make sure your electrical receptacle has the same configuration as your air conditioner’s plug. If different, consult a Licensed Electrician.

Do not use plug adapters.

Do not use an extension cord.

Do not remove ground prong.

Always plug into a grounded 3 prong oulet. Failure to follow these instructions can result in death, fire, or electrical shock.

Figure 1

RESET

TEST

WARNING:

TEST BEFORE EACH USE!

1.PRESS REST BUTTON.

2.PLUG LCDI INTO POWER RECEPTACLE.

3.PRESS TEST BUTTON, RESET BUTTON SHOULD POP UP.

4.PRESS RESET BUTTON FOR USE.

DO NOT USE IF ABOVE TEST

FAILS.

WHEN GREEN LIGHT IS ON.

IT IS WORKING

PROPERLY!

FRR072