HEAT/COOL ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS
Problem | Possible Cause | Possible Solution | |
Room temperature | Bad indoor ambient thermistor | Check error codes. Replace if needed. | |
uneven |
|
| |
Opened doors, windows, etc. | Close doors, windows, etc. | ||
(Heating cycle) | |||
|
|
|
Problem | Possible Cause | Possible Solution | |
| Incorrect wiring | Refer to appropriate wiring diagram | |
Unit will not | Bad outdoor coil thermistor or | Check error codes. Replace needed part. | |
electronic control board | |||
defrost |
| ||
|
| ||
| Outdoor temperature below | Ambient temperature will have to | |
| rise above 32 degrees F for frost | ||
| 32 degrees | ||
| to melt | ||
|
| ||
|
|
|
Problem | Possible Cause | Possible Solution | |
| Dirty filter | Clean as recommended in Owner’s Manual | |
|
| Check heat rise across coil. If unit operates | |
| Unit undersized | efficiently, check if insulation can be added | |
| to attic or walls. If insulation is adequate, | ||
|
| ||
|
| recommend additional unit or larger one | |
Does not heat | Outdoor | ||
of control. If temperature is below 38°F, | |||
models) | |||
adequately | replace control | ||
| |||
| Heater | Check for adequate fan air across heater. | |
| Check control for open at 160°F & close at | ||
| off | ||
| 150°F | ||
|
| ||
| Shorted supplementary heater | Ohmmeter check, approx. | |
|
|
| |
| Incorrect wiring | Check applicable wiring diagram | |
|
|
|
37