TROUBLESHOOTING & REPAIR

 

F-12

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSSIBLE AREAS OF

 

 

 

 

 

 

PROBLEMS

RECOMMENDED

 

 

 

 

(SYMPTOMS)

 

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIG MODE PROBLEMS

 

 

 

 

 

 

 

 

Machine has low output when in

 

 

1. Machine must be in “Local”

 

Machine controls may be set incor-

 

 

 

TIG 4-Step Mode.

 

 

Control Mode when 4-Step is

 

rectly.

 

 

 

 

 

 

 

 

used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact The Lincoln Electric

 

 

 

 

 

 

 

 

 

 

Service Department (216) 383-

 

 

 

 

 

 

 

 

 

 

2531 or 1-800-833-9353 (WELD).

 

 

 

 

 

 

 

 

 

 

 

 

 

Weak high frequency - machine

 

 

1. Spark gap may be misadjusted.

 

1.

Check for an open or arcing

 

 

 

has normal welding output.

 

 

Check and reset per

 

 

high frequency component.

 

 

 

 

 

 

 

 

maintenance instructions.

 

 

Replace as required.

 

 

 

 

 

 

 

 

2. Improper shielding gas flow.

 

 

(Examples. R3, R4, C2.) Refer

 

 

 

 

 

 

 

 

 

to wiring diagram.

 

 

 

 

 

 

 

 

Adjust for a flow of 10 to 30

 

 

 

 

 

 

 

 

 

 

 

 

CFH (4.7 to 14.1 l/min.) for

 

2.

If spark is weak at the spark

 

 

 

 

 

 

 

most applications.

 

 

gap check or replace high fre-

 

 

 

 

 

 

 

3. Work and electrode cables in

 

 

quency circuit. ( Examples. T3,

 

 

 

 

 

 

 

 

 

C3, L3, L4.)

 

 

 

 

 

 

 

 

poor condition allowing high

 

 

 

 

 

 

 

 

 

 

 

 

frequency to “Leak Off”. Use

 

 

 

 

 

 

 

 

 

 

 

 

good quality cables with a high

 

 

 

 

 

 

 

 

 

 

 

 

natural rubber content, such

 

 

 

 

 

 

 

 

 

 

 

 

as Lincoln Stable Arc Cable.

 

 

 

 

 

 

 

 

 

 

 

 

Cables should be as short as

 

 

 

 

 

 

 

 

 

 

 

 

possible.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The display shows zero amps, but

 

 

1. The arc start switch or amptrol

 

1.

Check Trigger circuit. See Arc

 

 

 

indicates open circuit voltage

 

 

may be defective. There should

 

 

Start Trigger Circuit Test.

 

 

 

 

(approximately 53V). The arc start

 

 

not be any continuity between

 

 

 

 

 

 

 

 

switch or amptrol is not actuated.

 

 

pins “D” and “E” on the arc start

2.

Control board may be faulty.

 

 

 

 

 

 

 

cable connector, unless the

 

 

Replace.

 

 

 

 

 

 

 

 

unit is actuated.

 

 

 

 

 

 

 

 

 

 

 

 

2. If an amptrol is not being used,

 

 

 

 

 

 

 

 

 

 

 

 

the machine must be in the

 

 

 

 

 

 

 

 

 

 

 

 

Local Control Mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353.

SQUARE WAVE TIG 255

Page 53
Image 53