TROUBLESHOOTING & REPAIR

 

ARC START TRIGGER CIRCUIT TEST

WARNING

Service and repair should only be performed by Lincoln Electric factory trained person- nel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safe- ty and to avoid electrical shock please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353 (WELD).

_____________________________________________________________________

CAUTION

If machine case sides and top are removed the case back and front must be support- ed. Failure to do this could result in mechanical or electrical damage to the TIG 255.

_____________________________________________________________________

TEST DESCRIPTION

The Arc Start Trigger Test determines if the wiring and connections are good from the six pin amphenol receptacle to the protection/snubber board and also from the protec- tion/snubber board to the control board.

MATERIALS NEEDED

Ohmmeter (Multimeter)

TIG 255 Wiring Diagrams (see Electrical Diagrams section of this manual)

Arc Start Trigger Circuit, (Figure F.10)