F-27

TROUBLESHOOTING & REPAIR

 

STATIC SCR TEST (continued)

REMOVE PLUGS J10 & J13

PROTECTION/SNUBBER

L9255

J10

J11

J12

J13

J14

J15

FIGURE F.11 - PROTECTION BOARD PLUG LOCATIONS

Return to

Section TOC

Return to

Master TOC

TEST PROCEDURE

1.Remove main supply power to machine

2.Remove plug J10 and J13 from the pro- tection/snubber board. Refer to Figure F.11.

3.Remove red insulating paint from heat sink test points. See Figure F.12. DO NOT DISASSEMBLE THE HEAT SINKS.

4.Using an analog ohmmeter test the resistance from anode to cathode of

SCR1. Reverse the meter leads and check from cathode to anode of SCR1.

A.If a low resistance is indicated in either direction SCR1 is faulty. Replace SCR assembly.

5.Repeat Step 4 testing SCR2, SCR3 and SCR4.

To further check the SCR’s functions use an SCR tester and proceed to active SCR test.

Return to

Return to

SCR3

CATHODE

SCR2

SCR4

ANODE

CATHODE

ANODE CATHODE

Return to Section TOC

Return to Master TOC

SCR1(3 & 4) (1 & 2)

ANODE

PLUG

P10

FIGURE F.12 - SCR TEST POINTS.