TROUBLESHOOTING & REPAIR

 

F-4

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

 

(SYMPTOMS)

 

 

MISADJUSTMENT(S)

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

 

 

The voltmeter reads “00” in Stick

 

 

1. Inspect to assure that the arc

 

 

1.

Check for loose connectors at

 

 

 

Mode, and there is no output from

 

 

start switch is in the on

 

 

 

the SCR bridge and at the

 

 

 

 

the machine when in the TIG

 

 

(closed) position when

 

 

 

Protection/Snubber board. (J10)

 

 

 

2-Step Mode.

 

 

welding in the TIG Mode.

 

 

 

and (J11). See Figure F.2 at

 

 

 

 

 

 

 

 

 

 

 

 

end of this Guide for location.

 

 

 

 

 

 

 

 

 

 

2.

Check the wiring to the Control

 

 

 

 

 

 

 

 

 

 

 

Transformer (T2). Observe

 

 

 

 

 

 

 

 

 

 

 

 

directions on decal.

 

 

 

 

 

 

 

 

 

 

 

3.

The Protection/Snubber board

 

 

 

 

 

 

 

 

 

 

 

may be faulty. See

 

 

 

 

 

 

 

 

 

 

 

 

Protection/Snubber Board

 

 

 

 

 

 

 

 

 

 

 

 

Continuity Test.

 

 

 

 

 

 

 

 

 

 

 

4.

Check the Control Transformer

 

 

 

 

 

 

 

 

 

 

 

(T2). See Control Transformer

 

 

 

 

 

 

 

 

 

 

 

Voltage Test.

 

 

 

 

 

 

 

 

 

 

 

5.

Check the polarity switch (S2)

 

 

 

 

 

 

 

 

 

 

 

for loose or broken connections.

 

 

 

 

 

 

 

 

 

 

6.

Check the SCR bridge. See

 

 

 

 

 

 

 

 

 

 

 

 

Static and Active SCR Tests.

 

 

 

 

 

 

 

 

 

 

 

7.

If all previous tests are OK -

 

 

 

 

 

 

 

 

 

 

 

 

then replace the Control board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Machine does not respond (no gas

 

 

1. Machine MUST be in one of

 

 

1.

Check trigger circuit. See Arc

 

 

 

flow, no high frequency and no

 

 

the TIG Modes.

 

 

 

Start Trigger Circuit Test

 

 

 

 

open circuit voltage) when arc

 

 

 

 

 

2.

Check the Control transformer

 

 

 

switch or amptrol is activated -

 

 

2. The arc start switch or amptrol

 

 

 

 

 

displays and fan working. Note:

 

 

may be defective. Check for

 

 

 

(T2). See Control Transformer

 

 

 

Machine may have OCV in the

 

 

continuity between pins “D”

 

 

 

Voltage Test.

 

 

 

 

Stick Mode.

 

 

and “E” on cable connector

 

 

3.

Protection/Snubber board may

 

 

 

 

 

 

 

when arc switch or amptrol is

 

 

 

 

 

 

 

 

 

activated.

 

 

 

be faulty. See

 

 

 

 

 

 

 

 

 

 

 

 

Protection/Snubber Board

 

 

 

 

 

 

 

 

 

 

 

 

Continuity Test.

 

 

 

 

 

 

 

 

 

 

 

4.

If all previous tests are OK -

 

 

 

 

 

 

 

 

 

 

 

 

then replace the Control board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353.

12/95 SQUARE WAVE TIG 255

Page 45
Image 45
Lincoln Electric SVM100-A service manual 12/95 Square Wave TIG