TROUBLESHOOTING & REPAIR

 

F-10

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

 

(SYMPTOMS)

 

 

MISADJUSTMENT(S)

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIG MODE PROBLEMS

 

 

 

 

 

 

 

 

 

Machine output is intermittently

 

 

1. Problem may be caused by

 

 

1.

Internal ground connections

 

 

 

lost. Gas flow and high frequency

 

 

high frequency interference.

 

 

 

may be loose. Check mounting

 

 

 

are also interrupted.

 

 

Make sure that the machine is

 

 

 

screws on the Protection/

 

 

 

 

 

 

 

 

grounded properly according

 

 

 

Snubber board and also on the

 

 

 

 

 

 

 

to the installation instructions.

 

 

 

Bypass board. All case screws

 

 

 

 

 

 

 

If there are other high

 

 

 

should be in place and tight.

 

 

 

 

 

 

 

frequency sources in the area,

 

 

2.

Protection/Snubber board may

 

 

 

 

 

 

 

make certain that they are

 

 

 

 

 

 

 

 

 

grounded properly.

 

 

 

be faulty. See Protection/

 

 

 

 

 

 

 

 

 

 

 

 

Snubber Board Continuity Test.

 

 

 

 

 

 

 

2. Check arc start switch or

 

 

3.

Check trigger circuit. See Arc

 

 

 

 

 

 

 

amptrol for proper operation

 

 

 

 

 

 

 

 

 

and loose connections.

 

 

 

Start Trigger Circuit Test.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Arc “Flutters” when TIG welding.

 

 

1. Tungsten electrode may be

 

 

1.

Check for loose shunt connec-

 

 

 

 

 

 

 

too large in diameter.

 

 

 

tions.- leads #221 and #222.

 

 

 

 

 

 

 

 

 

 

 

Refer to wiring diagram.

 

 

 

 

 

 

 

 

2. Tungsten not “Sharp” when

 

 

2.

Check polarity switch for loose

 

 

 

 

 

 

 

welding in DC negative mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

or faulty connections.

 

 

 

 

 

 

 

 

3. If helium is used as a

 

 

3.

SCR bridge may be faulty. See

 

 

 

 

 

 

 

shielding gas, then reduce the

 

 

 

 

 

 

 

 

 

percentage of helium.

 

 

 

Static and Active SCR Tests.

 

 

 

 

 

 

 

4. Adjust flow rate of shielding

 

 

4.

Protection/Snubber board may

 

 

 

 

 

 

 

gas.

 

 

 

be faulty. See Protection/

 

 

 

 

 

 

 

 

 

 

 

 

Snubber Board Continuity Test.

 

 

 

 

 

 

 

5. Check hoses and connections

 

 

5.

Check R3, R4 and C2 in the

 

 

 

 

 

 

 

for leaks.

 

 

 

 

 

 

 

 

 

 

 

 

 

high voltage transformer prima-

 

 

 

 

 

 

 

 

 

 

 

ry circuit. Refer to wiring dia-

 

 

 

 

 

 

 

 

 

 

 

gram.

 

 

 

 

 

 

 

 

 

 

 

6.

The Control board may be

 

 

 

 

 

 

 

 

 

 

 

 

faulty.-Replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353.