Return to Section TOC

Return to Section TOC

to Section TOC

Return to Master TOC

Return to Master TOC

to Master TOC

F-35

TROUBLESHOOTING & REPAIR

 

TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED

DC TIG MODE

CAUTION

HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.

Perform all voltage and waveform checks with high frequency circuit OFF.

_____________________________________________________________________

CH1

0 volts

20 volts

2ms

MACHINE LOADED TO 200 AMPS AT 50 VDC

Return

Return to Section TOC

Return

Return to Master TOC

This is a typical DC (+) output voltage wave- form generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 2 milliseconds in time. The machine was loaded with a resistance grid bank. The TIG 255 display read 200 amps at 50VDC.

Note: Scope probes connected at machine

output studs: (+) probe to electrode, (–) probe to work.

SCOPE SETTINGS

Volts/Div

20 V/Div.

Horizontal Sweep

2 ms/Div.

Coupling

DC

Trigger

Internal

 

 

SQUARE WAVE TIG 255

Page 76
Image 76
Lincoln Electric SVM100-A Typical Output Voltage Waveform Machine Loaded DC TIG Mode, Machine Loaded to 200 Amps AT 50 VDC