Lincoln Electric SVM100-A service manual SCR Operation Square Wave TIG

Models: SVM100-A

1 100
Download 100 pages 25.78 Kb
Page 39
Image 39

Master TOC

 

THEORY OF OPERATION

E-6

SCR OPERATION

Return to

Return to Section TOC

Return to

Return to Master TOC

A silicon controlled rectifier (SCR) is a three terminal device used to control rather large currents to a load. An SCR acts very much like a switch. When a gate signal is applied to the SCR it is turned ON and there is current flow from anode to cathode. In the ON state the SCR acts like a closed switch. When the SCR is turned OFF there is no current flow from anode to cathode thus the device acts like an open switch. As the name suggests, the SCR is a rectifier, so it passes current only during positive half cycles of the AC sup- ply. The positive half cycle is the portion of the sine wave in which the anode of the SCR is more positive than the cathode.

When an AC supply voltage is applied to the SCR, the device spends a certain portion of the AC cycle time in the on state and the remainder of the time in the off state. The amount of time spent in the ON state is controlled by the Gate.

An SCR is fired by a short burst of current into the gate. This gate pulse must be more positive than the cathode voltage. Since there is a standard PN junc- tion between gate and cathode, the voltage between these terminals must be slightly greater than 0.6V. Once the SCR has fired it is not necessary to continue the flow of gate current. As long as current continues to flow from anode to cathode the SCR will remain on. When the anode to cathode current drops below a minimum value, called holding current, the SCR will shut off. This normally occurs as the AC supply volt- age passes through zero into the negative portion of the sine wave. If the SCR is turned on early in the positive half cycle, the conduction time is longer resulting in greater SCR output. If the gate firing occurs later in the cycle the conduction time is less resulting in lower SCR output.

Return to Section TOC

Return to Master TOC

ANODE

INPUT

CATHODE

OUTPUT

GATE

NOTE: AS THE GATE PULSE IS APPLIED LATER IN THE CYCLE THE SCR OUTPUT IS DECREASED.

Return to Section TOC

Return to Master TOC

GATE

SCR OPERATION

SQUARE WAVE TIG 255

Page 39
Image 39
Lincoln Electric SVM100-A service manual SCR Operation Square Wave TIG