Return to Section TOC

Return to Section TOC

Section TOC

Return to Master TOC

Return to Master TOC

Master TOC

F-31

TROUBLESHOOTING & REPAIR

 

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM

DC STICK MODE

CAUTION

HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.

Perform all voltage and waveform checks with high frequency circuit OFF.

_____________________________________________________________________

CH1

0 volts

50 volts

2ms

Return to

Return to Section TOC

Return to

Return to Master TOC

This is the typical DC (+) output voltage waveform generated from a properly operat- ing machine. Note that each vertical divi- sion represents 50 volts and that each hori- zontal division represents 2 milliseconds in time.

Note: Scope probes connected at machine

output studs: (+) probe to electrode, (–) probe to work.

SCOPE SETTINGS

Volts/Div

50 V/Div.

Horizontal Sweep

2 ms/Div.

Coupling

DC

Trigger

Internal

 

 

SQUARE WAVE TIG 255

Page 72
Image 72
Lincoln Electric SVM100-A service manual Normal Open Circuit Voltage Waveform DC Stick Mode, Scope Settings