7-18TROUBLESHOOTING THE BASKET LIFT SYSTEM

If the basket lift motors are activating, but the basket lift fails to raise

or lower, or if its movement is erratic, the probable cause is

jamming or binding of the basket lift rods. Apply a light-weight white

grease (such as LubriplateTM) to the rods. If this does not correct

the problem, check for bent or otherwise damaged rods and links,

and for loose bellcranks.

TROUBLESHOOTING
THE BASKET LIFT
With the basket lift
in the UP position, is 27-33VDC
present at Pin 7 or 9 of IFB 15-pin
connector (0 volts if in DOWN
position)?
Computer has failed.
Replace.
No
Yes
Yes
With the basket lift in the same
position as for the previous check, is
line voltage present at the Common
terminal of the switch?
With the basket lift
in the UP position, is line voltage
present at the NC (lower) terminal of
the microswitch (middle terminal if in
DOWN position)?
IFB has failed.
Replace.
No
Switch has failed.
Replace.
No
Motor has failed.
Replace.
Yes