CHAPTER 3: OPERATING INSTRUCTIONS

FBCR18 & FBKR18 SERIES GAS RETHERMALIZERS

CHAPTER 3: OPERATING INSTRUCTIONS

3.1Introduction

3.1Introduction WARNING

The on-site supervisor is responsible for ensuring that operators are made aware of the inherent hazards of operating a gas-fired heated water system, particularly the aspects of draining and cleaning procedures.

Mechanically, the FBCR18 and FBKR18 rethermalizers are virtually identical. The FBKR18 units have a manual fill switch in addition to the AutoFill feature.

The primary difference between the two rethermalizers is the controller. Both units use modified Computer Magic III (CM III) computers. Although the computers are very similar in appearance (and to standard CM III computers), they are not interchangeable.

3.2FBCR18 Series Computer

This computer has 12 programmable product buttons and a “chill” switch. The chill switch shuts off the burners, but does not turn off the computer. This allows unused product to be quickly cooled before being returned to a refrigerator or freezer.

The product buttons are multi-functional. In programmed for a distinct rethermalizing time. initiates a specific timed countdown.

the programming mode, each button can be In the rethermalizing mode, pressing a button

1

2

3

4

1

 

5

6

 

5

 

 

FBCR18 Series Computer

1

LED Displays

 

4

Power Switch

2

Chill Switch

 

5

Product Buttons

3

Temperature Check/Program Lock

6

Program Mode Switch

3-1