Frymaster FBKR18 Series, FBCR18 manual Troubleshooting Guides

Models: FBKR18 Series FBCR18

1 60
Download 60 pages 39.53 Kb
Page 29
Image 29
5.2Troubleshooting Guides

5.2Troubleshooting Guides

COOKPOT DID NOT

FILL WHEN UNIT WAS

TURNED ON. WATER

SUPPLY TO UNIT

VERIFIED TO BE ON.

Computer is not functioning.

 

 

 

 

 

Did anything

Probable causes are failed 12V

 

 

 

 

appear in CM III display

 

 

No

 

transformer, failed interface

 

 

 

 

when unit was

 

 

 

 

 

board, or failed computer.

 

 

 

 

 

turned on?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open control panel

 

 

 

 

 

 

 

by removing screws

 

 

 

 

 

 

 

in upper corners.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is WATER

 

 

 

LED on interface board

 

 

 

 

 

 

 

illuminated?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use bottle brush to

 

 

Yes

 

clean water level

 

 

 

 

 

sensors.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Probable causes are a failed

No

Did LED

 

 

interface board or a failed

 

 

illuminate?

 

 

high-level water sensor.

 

 

 

 

 

 

 

 

 

Yes

 

 

Problem resolved.

Yes

Did unit

No

Probable causes are a failed

water solenoid or a failed

begin to fill?

 

 

 

interface board.

 

 

 

 

Call FASC.

5-2

Page 29
Image 29
Frymaster FBKR18 Series, FBCR18 manual Troubleshooting Guides