PROGRAMMING THE FBCR18 SERIES COMPUTER

PROGRAMMING THE FBCR18 SERIES COMPUTER

1.Turn the computer on by pressing the Power OPERATING THE FBCR18 SERIES RETHERMALIZER switch.

2.Press the Program Mode USING THE FBCR18 CHILL FEATURE switch. CodE appears in the left display. Press, in sequence, product buttons 1, 6, 5, and 10. (Press switch again to exit the programming mode.)

NOTE 1: The programming mode is not available while the computer is rethermalizing; the display will flash BUSY.

NOTE 2: To toggle between Fahrenheit and Celsius temperature display, press the Program Mode Manual background switch, then enter the code 1 6 5 8 by pressing the corresponding product buttons. Next, press the Temperature Check/Program Lock Manual backgroundManual background switch to lock in the new display option.

3.SP- is displayed in the left window and the setpoint in the right. Use the product buttons to change the temperature up to 205°F (96°C). For example, pressing 1, 9, and 5 programs the setpoint for 195°. When the correct setpoint is displayed, press the Program Mode Manual background switch.

4.SELP (Select Product) appears in the display and the LEDs in the product buttons blink. Press any of the product buttons to select it for programming.

5.PULL appears in the display. Press the product buttons to enter the desired heating time in minutes and seconds. Press the Program Mode Manual background switch to lock it in.

6.SELP again appears in the display. To program the heating time for another product, press the product button to be associated with it and repeat Step 5.

7.Press the Program Lock Manual background switch to exit the programming mode.

OPERATING THE FBCR18 SERIES RETHERMALIZER

1.Press the Power Manual background switch. The AutoFill feature will activate if the water level is below the upper water level sensor.

2.CYCL appears in the display and the unit enters a burner on/off cycle until the water in the cookpot reaches 180°F (82°C). At that time, the display changes to -Lo-and the burners fire continuously. When the water in the cookpot is within 3°F of setpoint, the display changes to four dashes (- - - -), indicating that the unit is ready for use. NOTE: To view the water temperature, press the Temperature Check Manual background button once. Press the button twice to display the setpoint.

3.After the four dashes appear in the display, place the product basket in the cookpot and press the corresponding product button. The display counts down the heating time. The display changes to PULL. The small LED in the product button blinks and an alarm sounds to alert you to remove the product. Press the button to silence the alarm.

USING THE FBCR18 CHILL FEATURE