3.5Boiling-Out the Cookpot

3.5Boiling-Out the Cookpot

3.6Shutting the Rethermalizer Down DANGER

Never leave the appliance unattended during the boil-out process. If the boil-out so- lution boils over, turn the appliance off immediately and let the solution cool for a few minutes before resuming the process. To lessen the chance of boil over, turn the appliance’s gas valve knob to the PILOT position occasionally.

To ensure that the cookpot is free of any contamination resulting from its manufacture, shipping, and handling during installation, the cookpot must be boiled out before first use.

1.Close the drain valve and fill the cookpot with a solution of cold water and 1 cup of boil-out solution or detergent.

2.Place the unit into operation in accordance with Section 3.4.

3.On FBCR18 Series units, program the setpoint for 195°F (91°C). Program one of the product buttons for 59 minutes and 59 seconds. Initiate the heating cycle by pressing the button.

On FBKR18 Series units, press the Boil (L) switch and allow the boil-out solution to boil for one hour.

4.After the solution heats for an hour, turn the unit off, allow the solution to cool, then add 2 gallons (7.75 liters) of cold water and stir. Drain the solution and clean the cookpot thoroughly.

5.Rinse the cookpot at least twice by filling with clean water and draining.

6.On FBCR18 Series units, reprogram the setpoint to the appropriate temperature, and reprogram the product button for the appropriate time.

3.6Shutting the Rethermalizer Down

1.Turn the unit off by pressing the Power Manual background switch (on FBKR18 units, press either switch).

2.Drain and clean the cookpot, put the cookpot cover in place, and turn the gas valve to the OFF position. (See illustration below.)

Honeywell

ON

OFF

Manual background CAUTION

The electronic circuitry in your computer can be affected adversely by current fluctuations and electrical storms. Should it fail to function or program properly for no apparent reason, the computer should be reset by unplugging the computer and plugging it back in. This could prevent a service call.