Frymaster FBKR18 Series, FBCR18 manual Burners Do Not Light

Models: FBKR18 Series FBCR18

1 60
Download 60 pages 39.53 Kb
Page 31
Image 31
BURNERS DO

BURNERS DO

NOT LIGHT.

Verify that correct setpoint has been programmed, that main gas supply valve is open, and that equipment gas valve is set to ON. Press ON/OFF button.

Did burners

Yes

light?

 

No

Use bottle brush to clean low water sensor. If burners still do not light, remove the cover over the water sensors and thoroughly clean them with a scouring pad.

Did burners

Yes

light?

 

No

Open control panel by

removing screws in each upper corner.

Is HEAT LED

on interface boardYes illuminated?

No

Problem is with a

failed interface board or a malfunctioning computer.

Call FASC.

5-4

Problem resolved.

Problem resolved.

Problem is with the gas supply or ignition system.

Call FASC.