Frymaster KSCFH18E operation manual Electrical Connections

Models: KSCFH18E

1 58
Download 58 pages 13.95 Kb
Page 14
Image 14

KSCFH18E COOL ZONE SERIES ELECTRIC FRYERS

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.3 Leveling the Fryer (cont.)

D.A fryer must be restrained to prevent tipping when installed in order to avoid the splashing of hot liquid. Restraints used can be straps or chains anchored to an immovable object (wall, floor anchor), or may be the manner of installation (installing the fryer in an alcove; battering to other appliances, etc.).

NOTE: The installation must be inspected after it is complete to ensure it meets the intent of these instructions. The on-site supervisor and/or operator(s) should be informed that the appliance is installed with restraints. If restraints are removed to move fryer (cleaning beneath and behind, relocation, etc.), ensure that they are re-installed when fryer is returned to its permanently installed position.

3.4 Electrical Connections

WARNING

The fryer MUST be connected to the voltage and phase as specified on the rating

and serial number plate located on the back of the fryer door.

A ground wire MUST be connected to the ground terminal provided near the input

power terminal block.

Plan and implement installation in accordance with local codes. Service connections should be made at the power input terminal block, located through the back lower portion of the fryer and through the component box, located under the control wireway. It is recommended that this connection be made by means of an approved (local code compliant), flexible-metallic or rubber- covered electrical cable and a quick-disconnect plug. If rigid or flexible-metal conduit connections are required, they must be made through the rear portion of the fryer cabinet, to the fryer input terminal block.

A.Wiring Diagram: It is attached to the inside of the fryer door. Amperage for each unit depends on the type of installation and accessories supplied with the unit. Consult the rating plate (inside door) for required amperage.