Chapter 10 Component Management
10.2 Functions in the Action Area for Component
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
699

Turning off the LED

The procedure to turn off an LED is as follows:
Procedure
1Click [Turn off locator beacon] in [Action].
A confirmation screen appears.
2Click the [OK] button.
The locator beacon is turned off.
3Click the [Done] button to return to the [Controller Enclosure] screen.
End of procedure
10.2.3 Add Channel Adapter Port
This function enables a CA port to be added without stopping the ETERNUS DX Disk storage system.
If the LED is already turned off, [Turn off locator beacon] cannot be selected.
This function is available only for the ETERNUS DX80 S2 model that is using one port for each CM.
CA ports for FC, iSCSI, FCoE, or SAS, host interfaces can be added.
When the general status of the ETERNUS DX Disk storage system is not normal, a CA port cannot be
added.
The 1-port type CA is also displayed as a 2-port type. To determine whether the CA is 1-port type or 2-port-
type, refer to the port number displayed in the [Internal Parts] tab in the "10.1.6 Channel Adapter Detail"
(page 655). Note that 1-port type CAs are not available in some regions.