If the Pad is attached to the scanner,

4 you can replace the Pad according to the following procedure.

a)Remove the pick spring.

b)Remove the pad from the pad holder. c)Attach a new pad to the pad

holder and fix it with the pick spring.

N O T E

Turn the pad upside down so that the pad holder pin fits with the pad hole.

Do not alter the shape of the pick spring.

• Attach the pick spring so that both ends of the pick spring are located on the pad.

Pad holder

Pad

Pick spring

5

Attach the pad ASY to the ADF

until it clicks in the reverse

sequence of step 3.

NOTE

Fit the pad ASY pin with the larger hole then slide to the right.

6 Close the ADF.

N O T E

Normally, set the select lever to “N”. Return the select lever if necessary.

REPLACEMENT OF PARTS

4-3

Page 40
Image 40
Fujitsu M3093DE/DG manual Attach the pad ASY to the ADF, Until it clicks in the reverse, Sequence of step