D.1.1.6 Dynamic threshold
fThe change was made to the bytes in the set window parameter as follows:
-Byte 3E
f M3096G: X00: Default; Simplified DTC, if IPC option is selected. X01 to XFF Reserved
f M3097G: DTC SELECTION BYTE
Byte 3E | b7 | b6 | b5 | b4 | b3 | b2 | b1 | b0 |
|
|
|
|
|
|
|
|
|
Reserved
DTC SELECTION
0 0: Default; Simplified DTC, if IPC II optioned.
0 1: Dynamic threshold
1 0: Simplified DTC, if IPC II optioned.
1 1: Reserved
Example: X00 is ™Default; Simplified DTC, if IPC II option is selected.
-Byte 2F
f M3096G: Reserved
f M3097G: The definitions of the byte are the same as those of M3097G control register #3. For further details, refer to OEM Manual 50FH5037E.
Restrictions:This byte is effective only when byte 3E is X40.
-Byte 30
f M3096G: Reserved
f M3097G: The definitions of the byte are the same as those of M3097E control register #4. For further details, refer to OEM Manual 50FH5037E.
Restrictions:This byte is effective only when byte 3E is X40.
fHow to specify the parameter
-When Simplified DTC is used:
Specified as ™Byte 17 (threshold)=X00, Byte 3E (DTC SELECTION)=X00 or X80.
-When Dynamic threshold is used:
Specify as ™Byte 17=X00, Byte 3E=X40, Byte 2F/30.
D $ 9