D.1.1.6 Dynamic threshold

fThe change was made to the bytes in the set window parameter as follows:

-Byte 3E

f M3096G: X￿00￿: Default; Simplified DTC, if IPC option is selected. X￿01￿ to X￿FF￿ Reserved

f M3097G: DTC SELECTION BYTE

Byte 3E

b7

b6

b5

b4

b3

b2

b1

b0

 

 

 

 

 

 

 

 

 

Reserved

DTC SELECTION

0 0: Default; Simplified DTC, if IPC II optioned.

0 1: Dynamic threshold

1 0: Simplified DTC, if IPC II optioned.

1 1: Reserved

Example: X￿00￿ is ™Default; Simplified DTC, if IPC II option is selected￿.

-Byte 2F

f M3096G: Reserved

f M3097G: The definitions of the byte are the same as those of M3097G control register #3. For further details, refer to OEM Manual 50FH5037E.

Restrictions:This byte is effective only when byte 3E is X￿40￿.

-Byte 30

f M3096G: Reserved

f M3097G: The definitions of the byte are the same as those of M3097E control register #4. For further details, refer to OEM Manual 50FH5037E.

Restrictions:This byte is effective only when byte 3E is X￿40￿.

fHow to specify the parameter

-When Simplified DTC is used:

Specified as ™Byte 17 (threshold)=X￿00￿, Byte 3E (DTC SELECTION)=X￿00￿ or X￿80￿.

-When Dynamic threshold is used:

Specify as ™Byte 17=X￿00￿, Byte 3E=X￿40￿, Byte 2F/30￿.

D $ 9