(d)A bit and field described as ™Reserved￿ are 0.

If this scanner receives a value other than 0, it returns error information as follows:

fStatus key: B©00001￿ (CHECK CONDITION)

fSense key: X©5￿ (ILLEGAL REQUEST)

The commands supported by this scanner are listed below.

 

 

Table 4.6 Commands

 

 

 

 

Command

Operation

 

Description

code (hex)

 

 

 

 

 

 

 

 

RESERVE UNIT

16

 

Declares the exclusive use of a logical unit

 

 

 

 

RELEASE UNIT

17

 

Cancels the declaration of the execlusive use of a

 

 

 

logical unit

 

 

 

 

INQUIRY

12

 

Examines the information regarding the target and

 

 

 

logical unit

 

 

 

 

REQUEST SENSE

03

 

Requests a target for sense data

 

 

 

 

SEND

1D

 

Requests a target for self>check

DIAGNOSTIC

 

 

 

 

 

 

 

TEST UNIT

00

 

Checks whether or not a logical unit is ready

READY

 

 

 

 

 

 

 

SET WINDOW

24

 

Sets a window

 

 

 

 

SET

C0

 

Sets subwindows

SUBWINDOW

 

 

 

 

 

 

 

SEND

2A

 

Sends Dither Matrix

 

 

 

 

OBJECT

31

 

Controls the automatic document feeder

POSITION

 

 

 

 

 

 

 

READ

28

 

Requests transfer of image data

 

 

 

 

MODE SELECT

15

 

Selects operating mode of the device.

 

 

 

 

MODE SENSE

1A

 

Requests operating mode of the device.

 

 

 

 

4 $ 21