D.1.1.7 Lamp timer function

fFunctions

-This function specifies how long the lamp will stay on.

-This must be specified with Mode select (Page code=X￿3D￿).

Format of Page Code X￿3D￿

 

 

 

 

 

 

 

 

 

 

 

 

Byte 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reserved

 

 

 

 

Page code = X￿3D￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 1

Parameter length = X￿06￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 2

 

Parameter

 

 

 

 

 

 

 

 

 

 

 

 

Byte 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 5

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

f Parameter

 

 

 

Byte 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X￿00￿: The default value is 60 seconds for this scanner.

X￿01￿ to X￿FF￿: Specifiable between 1 to 255 seconds (X￿FF￿)

D.1.1.8 Added sense code

Following sense code are added.

The blown lamp fuse;

™Sense key=X￿04￿, Add.sense code=X￿80￿, Add.sense qualifier=X￿03￿￿.

Interlock switch is opened;

™Sense key=X￿02￿, Add.sense code=X￿80￿, Add.sense qualifier=X￿01￿￿.