D.1.1.7 Lamp timer function
fFunctions
-This function specifies how long the lamp will stay on.
-This must be specified with Mode select (Page code=X3D).
Format of Page Code X3D |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
Byte 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Reserved |
|
|
|
| Page code = X3D |
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Byte 1 | Parameter length = X06 | ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Byte 2 |
| Parameter |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
Byte 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Byte 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Byte 5 |
|
|
| Reserved |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
Byte 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Byte 7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
f Parameter |
|
|
| Byte 2 |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X00: The default value is 60 seconds for this scanner.
X01 to XFF: Specifiable between 1 to 255 seconds (XFF)
D.1.1.8 Added sense code
Following sense code are added.
The blown lamp fuse;
™Sense key=X04, Add.sense code=X80, Add.sense qualifier=X03.
Interlock switch is opened;
™Sense key=X02, Add.sense code=X80, Add.sense qualifier=X01.
D $ 10