(k)Vender unique parameter: byte 28 and after

Specifies, in byte 28 and after, a vender unique identification parameter, including items such as outline, emphasis, and automatic separation, as required. This parameter is specified in the following format. This parameter does not need data until byte 3E. (It is unnecessary to transfer the unnecessary parameter but the intermediate parameter cannot be omitted.

28

Vender unique identification code

29

d Pattern number

2A

 

Outline extraction

2B

 

Image emphasis

2C

 

Automatic separation

2D

 

Reserved

2E

 

Variance rate

2F

 

30

 

31

 

32

 

33

 

34

 

35

 

36

Reserved

37

 

38

 

39

 

3A

 

3B

 

3C

 

3D

 

 

 

3E

DTC selection

fVender unique identification code: byte 28

Specifies a vender unique identification code. For this scanner, X©00￿ must be specified. If other value is specified, this scanner returns the following error information:

f Status:

00001 (CHECK CONDITION)

fSense key: X©5￿ (ILLEGAL REQUEST)

fd pattern: byte 29

Specifies d pattern number for subwindow. For details, see the explanation of the SET WINDOW command.

fOutline extraction: byte 2A

Specifies the outlining for the subwindow. For details, see the explanation of the SET WINDOW command.

4 $ 62