j.Command>specific information bytes: Bytes 8 to B
On this scanner, this field is not supported and is fixed to X©00000000.
k.Additional sense code, additional sense code qualifier: Bytes C and D
A combination of these fields specifies detailed information about the error reported in the sense key. This scanner reports the following information:
Sense | Additional | Additional |
| |
sense code | Description | |||
key | sense code | |||
qualifier |
| |||
|
|
| ||
|
|
|
| |
0 | 00 | 00 | No> sense | |
|
|
|
| |
2 | 00 | 00 | Not ready | |
|
|
|
| |
2 | 80 | 01 | Interlock switch is opened | |
|
|
|
| |
3 | 80 | 01 | Jam | |
|
|
|
| |
3 | 80 | 02 | ADF cover open | |
|
|
|
| |
3 | 80 | 03 | Document chuter empty of paper | |
|
|
|
| |
3 | 80 | 04 | Detects job separation sheet | |
|
|
| (See Appendix A.5) | |
|
|
|
| |
4 | 80 | 01 | Blown fuse for FB motor | |
|
|
|
| |
4 | 80 | 02 | Blown fuse for heater | |
|
|
|
| |
4 | 80 | 03 | Blown lamp fuse | |
|
|
|
| |
4 | 80 | 04 | Blown fuse for ADF motor | |
|
|
|
| |
4 | 80 | 05 | Mechanical alarm | |
|
|
|
| |
4 | 80 | 06 | Optical alarm | |
|
|
|
| |
4 | 44 | 00 | Abnormal internal target | |
|
|
|
| |
4 | 47 | 00 | SCSI parity error | |
|
|
|
| |
5 | 20 | 00 | Invalid command | |
|
|
|
| |
5 | 24 | 00 | Invalid field in CDB | |
|
|
|
| |
5 | 25 | 00 | Unsupported logical unit | |
|
|
|
| |
5 | 26 | 00 | Invalid field in parameter list | |
|
|
|
| |
5 | 2C | 02 | Wrong window combination | |
|
|
|
| |
6 | 00 | 00 | UNIT ATTENTION | |
|
|
|
| |
B | 43 | 00 | Message error | |
|
|
|
| |
B | 80 | 01 | Image transfer error | |
|
|
|
|
4 $ 33