n. Product identification: Bytes 10 to 1F
Indicates the product name in ASCII code. The name is left>justified, with the blank filled with spaces (X©20). This scanner returns one of the following names:
M3097G | without option |
M3097Gi | with image processing II option |
M3097Gm | with CMPII option |
M3097Gim | with image processing II option and CMP II option |
o.Product revision level: Bytes 20 to 23
Indicates the version number of the product in ASCII code. This number is left> justified, with the blank filled with spaces (X©20).
4.4.4REQUEST SENSE command
The following table shows the normal sequence of the REQUEST SENSE command when used with this scanner.
Step | Bus phase | Initiator operation | ¨ Æ | Target operation |
|
|
|
|
|
1 | BUS FREE | Verifies bus free |
|
|
|
|
|
|
|
2 | ARBITRATION | Obtains bus>usage |
|
|
|
| right |
|
|
|
|
|
|
|
3 | SELECTION | Selects target | Æ |
|
|
|
|
|
|
|
|
|
| Drives BSY signal |
|
|
|
|
|
4 | MESSAGE OUT | Selects logical unit | Æ |
|
|
|
|
|
|
5 | COMMAND | Specifies | Æ |
|
|
| REQUEST SENSE |
|
|
|
| (CDB) |
|
|
|
|
|
|
|
6 | DATA IN |
| ¨ | Reports sense data |
|
|
|
|
|
7 | STATUS |
| ¨ | Reports GOOD status |
|
|
|
|
|
8 | MESSAGE IN |
| ¨ | Reports message (Command |
|
|
|
| Complete) |
|
|
|
|
|
|
|
|
| Releases BSY signal |
|
|
|
|
|
9 | BUS FREE |
|
|
|
|
|
|
|
|
4 $ 29