(4)Sequential starting of spindle motors
After power is turned on to the IDD, a large amount of current flows in the +12 VDC line when the spindle motor rotation starts. Therefore, if more than one IDD is used, the spindle motors should be started sequentially using one of the following procedures to prevent overload of the power supply unit. For how to set a spindle motor start control mode, see Subsection 5.3.2.
a)Issue START/STOP commands at
b)Turn on the +12 VDC power in the power supply unit at
(5)Power supply to SCSI terminating resistor
If power for the terminating resistor is supplied from the IDD to other SCSI devices through the SCSI bus, the
A method of power supply to the terminating resistor is selected with a setting terminal on the IDD. See Subsection 5.3.2 for this selection.
For the electrical condition of supplying power to the terminating resistor, refer to Subsection 1.4.2 in SCSI Physical Interface Specifications.
(6)Noise filter
To eliminate AC line noise, a noise filter should be installed at the AC input terminal on the IDD power supply unit. The specification of this noise filter is as follows:
∙ Attenuation: 40 dB or more at 10 MHz
∙ Circuit construction:
Figure 4.15 AC noise filter (recommended)
4 - 13 |