IMPORTANT
1.Set the SCSI ID so that there are no duplicates between SCSI devices on the same SCSI bus.
2.The priority of SCSI bus use in ARBITRATION phase is determined by SCSI ID as follows:
7 > 6 > 5 > 4 > 3 > 2 > 1 > 0 > 15 > 14 > 13 > 12 > 11 > 10 > 9 > 8
5.3.2Each mode setting
(1)Setting terminal power supply
Refer to Table 5.2 for controlling the supply of power from the drive to the SCSI terminal resistance power source (TERMPOW). However, this setting may not be used with SCA2 type 16
Table 5.2 Setting SCSI terminal power supply
Supply on/off of SCSI terminating resistor power from IDD | CN6 | |
|
| |
Supply off | Open | |
|
|
|
Supply on | Short | (*1) |
|
|
|
*1 Setting at factory shipment
(2)Motor start mode
Set how to control the starting of the IDD spindle motor according to Table 5.3. This setting only determines the operation mode when the power supply is turned on or the microcode is downloaded. In both modes, stopping or restarting the spindle motor can be controlled by specifying the START/STOP UNIT command.
This setting is not provided for SCA2 type
Table 5.3 Motor start mode setting
Start timing of the spindle motor | CN6 | |
|
| |
Starting of the motor is controlled with the START/STOP UNIT command. | Open | |
|
| |
The motor is started immediately after the power supply is turned on or the | Short (*1) | |
microcode is downloaded. | ||
| ||
|
| |
*1 Setting at factory shipment |
|
Refer to Chapter 3 of the SCSI Logical Interface Specifications for details of the START/STOP UNIT command.