5.3.4Mode settings
In addition to the previously described settings using setting terminals, the IDD is provided with several mode settings. The mode settings are enabled by specifying the CHANGE DEFINITION command. Table 5.6 lists the mode settings and their settings at factory shipment.
Refer to Section 3.1.4 of the SCSI Logical Interface Specifications for details of the command.
Table 5.6 Default mode settings (by CHANGE DEFINITION command)
Mode setting | Contents |
|
|
SCSI level |
|
|
|
SYNCHRONOUS DATA TRANSFER REQUEST message | Sent from IDD |
sending |
|
|
|
UNIT ATTENTION report mode | Reported |
|
|
Reselection retry count | Not restricted |
|
|
WIDE DATA TRANSFER REQUEST message sending | Sent from IDD |
|
|
Reselection | 250 ms |
|
|
| 0 sec (MAx3xxxSP) |
Spindle motor start delay time | 12 sec × SCSI ID |
| (MAx3xxxSC) |
|
|
5 - 10 |