CHAPTER 5 INSTALLATION
5.1Notes on Handling Drives
5.2Connections
5.3Setting Terminals
5.4Mounting Drives
5.5Connecting Cables
5.6Confirming Operations after Installation and Preparation for Use
5.7Dismounting Drives
This chapter describes the notes on handling drives, connections, setting switches and plugs, mounting drives, connecting cables, confirming drive operations after installation and preparation for use, and dismounting drives.
5.1Notes on Handling Drives
(1)General notes
a)Do not give the drive shocks or vibrations exceeding the value defined in the standard because it may cause critical damage to the drive. Especially be careful when unpacking.
b)Do not leave the drive in a dirty or contaminated environment.
c)Since static discharge may destroy the CMOS semiconductors in the drive, note the following after unpacking:
∙Use an antistatic mat and body grounding when handling the drive.
∙Hold the DE when handling the drive. Do not touch PCAs except for setting.
(2)Unpackaging
a)Use a flat work area. Check that the "This Side Up" sign side is up. Handle the package on soft material such as a rubber mat, not on hard material such as a desk.
b)Be careful not to give excess pressure to the internal unit when removing cushions.
c)Be careful not to give excess pressure to the PCAs and interface connector when removing the drive from the antistatic bag.
d)Do not remove the sealing label or cover of the DE and screws.
| 5 - 1 |