Table E.1 SCSI interface function specifications (3 of 8)
: Provided ×: Not provided
|
|
|
|
| Item | Specification |
| MODE SELECT | (15) | Ο | |||
|
| PF=(page format) | Ο (Specified value | |||
|
|
|
|
|
| ignored) |
|
| Page 1: Read/write error recovery | Ο (12 B: Savable) | |||
|
|
|
| AWRE (Automatic Write Reallocation Enabled) | × (Specified value | |
|
|
|
|
|
| ignored) |
|
|
|
| ARRE (Automatic Read Reallocation Enabled) | Ο (Changeable) | |
|
|
|
| TB | (Transfer Block) | Ο (Changeable) |
|
|
|
| RC | (Read Continuous) | Ο (Changeable) |
Command |
|
|
| EER | (Enable Early Recovery) | Ο (Changeable) |
|
|
| PER | (Post Error) | Ο (Changeable) | |
(Group 0) |
|
|
|
|
|
|
|
|
| DTE | (Disable Transfer on Error) | × (Specified value | |
|
|
|
| |||
|
|
|
|
|
| ignored) |
|
|
|
| DCR | (Disable Correction) | Ο (Changeable) |
|
|
|
| Retry count at read | Ο (Changeable) | |
|
|
|
| Correctable bit length | Ο (Not changeable) | |
|
|
|
| Head offset count | × | |
|
|
|
|
|
| |
|
|
|
| Data strobe offset count | × | |
|
|
|
|
|
| |
|
|
|
| Retry count at write | Ο (Changeable) | |
|
|
|
| Recovery processing time restriction | Ο (Changeable) | |
|
| Page 2: Disconnection/reconnection | Ο (16 B: Savable) | |||
|
|
|
| Ο (Changeable) | ||
|
|
|
| Ο (Changeable) | ||
|
|
|
| Bus inactivity restriction | Ο (Not changeable) | |
|
|
|
| Disconnection time restriction | × | |
|
|
|
| Connection time restriction | × | |
|
|
|
| Maximum burst length | × | |
|
|
|
|
|
| |
|
|
|
| DTDC (data transfer disconnect control) | Ο (Changeable) | |
|
|
|
| |||
*1 Fujitsu- | specific function |
|
|
E - 4 |
|