Fujitsu MHV2060AS, MHV2080AS, MHV2040AS manual SET MAX SET Password FR = 01h

Models: MHV2060AS MHV2080AS MHV2040AS

1 280
Download 280 pages 57.54 Kb
Page 181
Image 181

5.3 Host Commands

At command issuance (I/O registers setting contents)

1F7H(CM)

1

1

1

1

1

0

0

1

1F6H(DH)

x

L

x

DV

Max head/LBA [MSB]

1F5H(CH)

Max. cylinder [MSB]/Max. LBA

 

 

 

1F4H(CL)

Max. cylinder [LSB]/Max. LBA

 

 

 

1F3H(SN)

Max. sector/Max. LBA [LSB]

 

 

 

1F2H(SC)

xx

 

 

 

 

 

 

VV

1F1H(FR)

xx

 

 

 

 

 

 

 

At command completion (I/O registers contents to be read)

1F7H(ST)

Status information

 

 

1F6H(DH)

x

x

x

DV

Max head/LBA [MSB]

1F5H(CH)

Max. cylinder [MSB]/Max. LBA

1F4H(CL)

Max. cylinder [LSB]/Max. LBA

1F3H(SN)

Max. sector/Max. LBA [LSB]

1F2H(SC)

xx

 

 

 

 

1F1H(ER)

Error information

 

 

SET MAX SET PASSWORD (FR = 01h)

This command requests a transfer of 1 sector of data from the host, and defines the contents of SET MAX password. The password is retained by the device until the next power cycle.

The READ NATIVE MAX ADDRESS command is not executed just before this command. The command is the SET MAX ADDRESS command if it is the command just after the READ NATIVE MAX ADDRESS command is executed.

At command issuance (I/O registers setting contents)

1F7H(CM)

1

1

1

1

1

0

0

1

1F6H(DH)

x

x

x

DV

xx

 

 

 

1F5H(CH)

xx

 

 

 

 

 

 

 

1F4H(CL)

xx

 

 

 

 

 

 

 

1F3H(SN)

xx

 

 

 

 

 

 

 

1F2H(SC)

xx

 

 

 

 

 

 

 

1F1H(FR)

01

 

 

 

 

 

 

 

C141-E221

5-105

Page 181
Image 181
Fujitsu MHV2060AS, MHV2080AS, MHV2040AS manual SET MAX SET Password FR = 01h