Table 1.3 Current and power dissipation
Mode of Operation | Typical RMS current (*1) [mA] | Typical Power (*2) [watts] | ||||
|
|
| ||||
+12 V | +5 V | |||||
|
|
| ||||
|
|
|
|
|
| |
Model | MPF3102AT | MPF3153/ | All Models | MPF3102AT | MPF3153/ | |
|
| MPF3204AT |
|
| MPF3204AT | |
|
|
|
|
|
| |
Spin up | 1600 | 1600 | 570 | 22.1 | 22.1 | |
| 1800 peak | 1800 peak | 600 peak |
|
| |
|
|
|
|
|
| |
Idle (Ready) (*3) | 175 | 185 | 400 | 4.1 | 4.2 | |
|
|
|
|
|
| |
R/W (On Track) (*4) | 240 | 250 | 500 | 5.4 | 5.5 | |
|
|
|
|
|
| |
Seek (Random) (*5) | 340 | 350 | 500 | 6.6 | 6.7 | |
Seek/W/R | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
Standby | 7 | 7 | 185 | 1.0 | 1.0 | |
|
|
|
|
|
| |
Sleep | 7 | 7 | 185 | 1.0 | 1.0 | |
|
|
|
|
|
|
*1 Current is typical rms except for spin up.
*2 Power requirements reflect nominalvalues for +12V and +5V power.
*3 Idle mode is in effect when the drive is not reading, writing, seeking, or executing any commands. A portion of the R/W circuitry is powered down, the spindle motor is up to speed and the Drive ready condition exists.
*4 R/W mode is defined as 50% read operations and 50% write operations on a single physical track.
*5 Seek/W/R mode is defined as 33% seek operations, 33% write operations and 33% read operations.
1 - 6 |