Table 5.5 Information to be read by IDENTIFY DEVICE command (3 of 5)
*11 Total number of user addressable sectors (LBA mode only.)
| MPF3102AT | MPF3153AT | MPF3204AT |
*2 |
| X‘3FFF’ |
|
*3 |
| X‘10’ |
|
*11 | X‘01316AF0’ | X‘1CA1E70’ | X‘262D5E0’ |
*12 Word 63: Multiword DMA transfer mode
Bit
Bit
Bit 1=1 Mode 1
Bit 0=1 Mode 0
*13 Word 64: Advance PIO transfer mode support status Bit
Bit
1 Mode 4
Bit 0=1 Mode 3, Mode 4
*14 Word 80: Major version number Bit
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0: Undefined
*15 Word 82: Support of command sets Bit 15: Reserved
Bit 14: NOP command supported = 0
Bit 13: Read Buffer command supported = 1
Bit 12: Write Buffer command supported = 1
Bit 11: Write Verify command supported (Old Spec.) = 0
Bit 10: Host Protected Area feature command supported = 1
Bit 9: Device Reset command supported = 0
Bit 8: SERVICE Interrupt supported = 0
Bit 7: Release Interrupt supported = 0
Bit 6: Lock Ahead supported = 1
Bit 5:
Bit 4: Packet command feature set supported = 0
Bit 3: Power Management feature set supported=1
Bit 2: Removable feature set supported=0
Bit 1: Security feature set supported=1
Bit 0: SMART feature set supported=1
5 - 32 |
|