The contents of the command block registers related to addresses after the transfer of a data block containing an erred sector are undefined. To obtain a valid error information, the host should retry data transfer as an individual requests.

At command issuance (I/O registers setting contents)

1F7H(CM)

1

1

0

0

0

1

0

1

 

 

 

 

 

 

 

1F6H(DH)

×

L

×

DV

 

Start head No. /LBA [MSB]

 

 

 

 

 

 

 

 

1F5H(CH)

 

Start cylinder No. [MSB]/ LBA

 

 

1F4H(CL)

 

Start cylinder No. [LSB] / LBA

 

 

1F3H(SN)

 

Start sector No.

 

 

/ LBA [LSB]

 

1F2H(SC)

 

 

Transfer sector count

 

 

1F1H(FR)

 

 

 

 

xx

 

 

 

At command completion (I/O registers contents to be read)

1F7H(ST)

 

 

 

Status information

 

 

 

 

 

 

 

 

1F6H(DH)

×

L

×

 

DV

 

End head No. /LBA [MSB]

 

 

 

 

 

 

1F5H(CH)

 

End cylinder No. [MSB] / LBA

1F4H(CL)

 

End cylinder No. [LSB] / LBA

1F3H(SN)

 

End sector No.

/ LBA [LSB]

1F2H(SC)

 

 

 

 

00H

 

1F1H(ER)

 

 

 

Error information

Note:

When the command terminates due to error, only the DV bit and the error information field are valid.

(7)WRITE DMA (X'CA' or X'CB')

This command operates similarly to the WRITE SECTOR(S) command except for following events.

The data transfer starts at the timing of DMARQ signal assertion.

The device controls the assertion or negation timing of the DMARQ signal.

The device posts a status as the result of command execution only once at completion of the data transfer.

When an error, such as an unrecoverable medium error, that the command execution cannot be continued is detected, the data transfer is stopped without transferring data of sectors after the erred sector. The device generates an interrupt using the INTRQ signal and posts a status to the host system. The format of the error information is the same as the WRITE SECTOR(S) command.

A host system can be select the following transfer mode using the SET FEATURES command.