2.3.2 Connection of monitor cable inside the monitor

Connect the monitor cable inside the monitor as below.

MONITOR REAR

VIEW

1

Cable Cover

Loosen two M4X10 pan-head screws.

2

Cable Entrance Plate

Unfasten three MX10

screws to remove cable

entrance plate.

Connect to

CONNECTOR Board.

NH5P to J575

NH6P to J577

NH3P to J579

VH3P to J576

3

MONITOR CABLE

Connect D-SUB connector to J560 on the INTERFACE Board.

Fasten ground wire with

M4X10 pan-head screw.

Unfasten top or bottom M4X10 pan-head screw fixing clamp plate. Lay cable in clamp and then close clamp plate.

Clamp Plate

4

5

CONNECTOR Board

INTERFACE Board

Fasten D-SUB connector

with screw.

Earth Terminal

1.Fasten cable entrance plate.

2.Close cable cover.

3.Fasten ground wire between earth terminal and ship's superstructure.

CAUTION

Ground the equipment to prevent electrical shock and mutual interference.

Figure 2-12 Connection of monitor

2-9

Page 28
Image 28