4.1.2 Connection of external power supply

An external power supply is necessary when the repeater signal is step-by-step type and the step voltage is below 20 V or output voltage is less than 5 W.

1.Cut the jumper wire JP1 on the GYRO CONVERTER Board when an external power supply is used.

2.Connect the gyro cable and power cable as shown below.

External Power Supply 20 - 135 VAC

20 - 100 VDC

Gyrocompass (Step type)

GYRO CONVERTER Board [A] 64P1106

J5

1R2

2R1/COM

Either connection in case of DC polarity.

S1

J4

1S1

S2

2 S2

 

S3

3 S3

COM

4 T

F.G.

5 F.G.

 

Figure 4-3 Connection of external power supply to GYRO CONVERTER Board

4.1.3 DIP switch, jumper wire settings

Default setting

The default setting of all DIP switches is off and all jumpers wire are set to "#1". (Note that the jumper wire JP1 is set at #1, #2, and #3.) In those settings the gyrocompass having the following characteristics can be directly connected; modification of the GYRO CONVERTER Board is not necessary.

AC synchronous signal: 50/60 Hz

Rotor voltage: 60 to 135 V AC

Stator voltage: 60 to 135 V AC

Gear ratio: 360X

Supply voltage: 30 to 135 V AC

If the specifications of the gyrocompass differ from those mentioned above, change jumper wire and DIP switch settings on the GYRO CONVERTER Board as appropriate. Settings may be changed according to gyrocompass specifications (page 4-4) or make and model of gyrocompass (page 4-5). For the location of DIP switches and jumper wires, see page 4-6.

4-3

Page 42
Image 42
Furuno FR-2115-B installation manual Connection of external power supply, DIP switch, jumper wire settings