How to attach NH connector

HOW TO ATTACH NH CONNECTOR TO SIGNAL CABLE

NH connector wire

Shrink tubing

NH connector

20mm

housing

 

1) Insert NH connector

2) Cut shrink tubing

wire into NH connector

in 20 mm lengths and

housing.

slip onto each wire.

Solder

 

3) Solder connector

4) Heat shrink

to signal cable.

tubing with solder-

 

ing iron.

Figure 2-15 How to attach NH connector

2.6AC Power Specification of Processor Unit

For 100 VAC or 220 VAC power, add or delete jumper wires on the PTU Board and change the power fuses inside the processor unit as shown in the table below according to ship's mains. The figure below shows the location of the power fuses and the jumper wires on the PTU Board.

Table 2-2 Jumper wire setting on the PTU board, fuse rating and power specification

PCB

Power Spec.

Antenna

JP1

JP2

JP3

JP4

JP91

JP92

Power

(VAC)

rpm

 

Fuse

 

 

 

 

 

 

 

 

03P9245A

100/110/115

24 rpm

 

YES

YES

YES

NO

NO

NO

10A

03P9245D

220/230

24 rpm

 

NO

NO

NO

YES

NO

NO

5A

 

PTUBoard

 

Jumper wire to use:

 

 

 

 

 

 

 

JP1: 0.8 dia. gilded wire

 

 

 

 

 

 

JP2, JP3, JP4, JP91, JP92: type ERD-S2TCOV

 

JP1

Fuse

JP2

JP92

JP3

JP4

JP91

03P9245

PTU Board

Figure 2-16 Processor unit, inside view

2-13

Page 32
Image 32
Furuno FR-2115-B installation manual AC Power Specification of Processor Unit, How to attach NH connector