Furuno FR-2115-B installation manual System Configuration, Data Sentences

Models: FR-2115-B

1 89
Download 89 pages 50.01 Kb
Page 8
Image 8

SYSTEM CONFIGURATION

ANTENNA UNIT

FR-2115-B: XN12AF-RSB-0074-062

XN12AF-RSB-0075-062

XN20AF-RSB-0074-062

XN20AF-RSB-0075-062

XN24AF-RSB-0074-062

XN24AF-RSB-0075-062

FR-2125-B: XN12AF-RSB-0074-063

XN12AF-RSB-0075-063

XN20AF-RSB-0074-063

XN20AF-RSB-0075-063

XN24AF-RSB-0074-063

XN24AF-RSB-0075-063

MONITOR

 

IEC 61162-1 (Input/Output) Navigator

RDP-124-M-ES

PROCESSOR UNIT

 

 

 

 

RPU-11

IEC 61162-1 (Input)

Speed Log

 

Alarm Kit

 

 

 

 

 

OP03-156

 

 

 

ARPA Board

Slave Display

 

 

ARP-26

FMD-8010

 

 

 

 

 

Video Plotter

 

 

 

RP-26

Performance

 

 

Gyro Converter

 

Gyrocompass

Monitor

 

GC-8

 

 

PM-30

 

 

 

 

AC spec or DC spec to be selected.

DC spec

Rectifier

RU-3424

Option

Ship's Mains 24/32 VDC or 100/110/115/220/230 VAC 1φ , 50/60 Hz

CONTROL UNIT

RCU-11

AC spec

Transformer Unit

RU-1803

440VAC

1φ , 50/60 Hz

I/O Data Sentences

Input: GGA, RMA, RMB, RMC, GLL, ZDA, VBW, VHW, VTG, MWV, VWT, VWR, VDR, DPT, DBT, DBS, MTW, BWR, BWC, WPT, RTE

Output: RAOSD, RARSD, RATTM