Setting method 1: DIP switch settings and gyrocompass specifications

1) Gyrocompass type

Gyrocompass

SW

SW

SW

JP1

type

1-4

1-5

1-6

 

 

 

 

 

 

AC

OFF

OFF

OFF

#1, #2,

synchronous

#3

 

 

 

 

 

 

 

 

DC

OFF

OFF

OFF

#2, #3,

synchronous

#4

 

 

 

 

 

 

 

 

DC step

ON

OFF

OFF

#4, #5,

#6

 

 

 

 

 

 

 

 

 

Full-wave

OFF

ON

0FF

#4, #5,

pulsating current

#6

 

 

 

 

 

 

 

 

Half-wave

ON,

ON

OFF

#4, #5,

pulsating current

#6

 

 

 

 

 

 

 

 

2) Frequency

Frequency

SW

SW

Remarks

 

1-7

1-8

 

 

 

 

 

50/60 Hz

OFF

OFF

AC synchronous

 

pulsating current

 

 

 

 

 

 

 

400 Hz

ON

OFF

AC synchronous

 

pulsating current

 

 

 

 

 

 

 

500 Hz

OFF

ON

AC synchronous

 

pulsating current

 

 

 

 

 

 

 

DC

ON

ON

DC synchronous

 

DC step

 

 

 

 

 

 

 

3) Rotor Voltage (between R1 & R2)

4) Stator Voltage (between S1 & S2)

Rotor Voltage

SW

JP3

2-1

 

 

 

 

 

20 to 45 VAC

ON

#2

 

 

 

30 to 70 VAC

OFF

#2

 

 

 

Stator

SW

SW

JP2

Voltage

2-2

2-3

 

 

 

 

 

20 to 45 VAC, or

OFF

OFF

#2

20 to 60 VDC

 

 

 

 

 

 

 

30 to 70 VAC, or

ON

OFF

#2

40 to 100 VDC

 

 

 

 

 

 

 

40 to 90 VAC

ON

#1

 

 

 

60 to 135 VAC

OFF

#1

 

 

 

40 to 90 VAC

OFF

ON

#1

 

 

 

 

60 to 135 VAC

ON

ON

#1

 

 

 

 

5) Ratio

Ratio

SW

SW

SW

1-1

1-2

1-3

 

 

 

 

 

360X

OFF

OFF

OFF

 

 

 

 

6) Supply Voltage

Stator

SW

SW

JP2

Voltage

2-2

2-3

 

 

 

 

 

20 to 45 VAC, or

OFF

OFF

#2

20 to 60 VDC

 

 

 

 

 

 

 

180X

ON

OFF

OFF

 

 

 

 

90X

OFF

ON

OFF

 

 

 

 

36X

OFF

ON

OFF

 

 

 

 

30 to 70 VAC, or

ON

OFF

#2

40 to 100 VDC

 

 

 

 

 

 

 

40 to 90 VAC

OFF

ON

#1

 

 

 

 

60 to 135 VAC

ON

ON

#1

 

 

 

 

7) AD-10 format data Tx interval

Select data transmitting interval for ports 1 to 6 with jumper wires JP6 and JP7. The Tx interval is available in 25 ms or 200 ms. 25 ms is for radar: 200 ms is for all other equipment.

8) NMEA interval

Tx Interval

SW2-4

 

 

2 seconds

ON

 

 

1second

OFF

 

 

4-4

Page 43
Image 43
Furuno FR-2115-B installation manual Rotor Voltage between R1 & R2 Stator Voltage between S1 & S2