SSB Radiotelephone
00080933802
Distress Alert Calling Procedure
Safety Instructions
Iii
Table of Contents
Sending Distress Alert
DSC Overview
Preparing TX Calls
Nbdp Preparations
Vii
Viii
General
Features
Foreword
PC Board Program No On Display Remarks
Program Number
DSC/watch receiver
Nbdp with optional Nbdp Terminal Unit IB-581/IB-583
FS-2570 250 W
System Configuration
Xii
FS-1570 150 W
FS-1570/2570
Specifications of SSB Radiotelephone
DSC/WATCH Keeping Receiver Digital Selective Calling
IB-581
IB-583
Interface
Description of controls
Power switch Turns the power on/off
Operational Overview
ControlsFURUNO
Panel Dimmer, LCD Contrast
Turning the Power On/Off
DSC standby screen
Indications
DSC standby screen
Radiotelephone screen
Scanning Routine DSC Frequencies
Loudspeaker
Manual Entry of Position and Time
Automatic Acknowledge On/Off
After last digit
Controls become inoperative
System Characteristics
Automatic setting of working frequency
Equipment priority
Power supply units
Power Supply Unit option
AC and DC power switches
Choosing class of emission
SSB Radiotelephone
Transmitting
Rotate the Enter knob to set band or channel desired
Choosing channel, frequency
Choosing channel
Choosing band and band channel with the Enter knob
Entering frequency with the numeric keys
Tuning
Choosing frequency
Enter frequency by one of the methods below
Monitoring transceiver output power
Using the handset
Displaying IA, IC, VC or RF
Reducing transmitter power
Monitoring traffic on intended transmit frequency
RF gain sensitivity adjustment
Receiving
Meter
Squelch frequency
Squelch control, squelch frequency
Noise blanker
Squelch on/off
Telex Communications
Intercom
Replace the cover Turn on the control unit
When Automatic Tuning Fails
Entry is selected push the Enter knob
User Channels
Registering user channels
Window shown below appears
Channels may be registered
Deleting individual user channels
FAX Enable/Disable
Press the Cancel key to close the menu
Deleting user channels
Speaker Setting in Off Hook
This page intentionally left blank
DSC Call
What is DSC?
Call over Public Switched Telephone Network Pstn
DSC Overview
Contents of a DSC call
Case of Accidental Trans Mission of the Distress Alert
Distress alert call and reply
Individual call
Audio Alarms
Basic procedure radiotelephone
Alarm Frequency interval
Distress receive call
Interpreting Call Displays
Receive calls
Received message
Individual receive call
Individual send call
Send calls
Distress send call
This page intentionally left blank
Russian version
Distress Operations
Sending Distress Alert
Distress Operations
Rotate Enter knob to scroll
Push the Enter knob to open the time input window
Push the Enter knob to open the Input Type menu
Compose
Communicating by Nbdp Terminal Unit
Receiving a Distress Alert
Action for ship receiving distress alert on MF band
Distress alert received on MF band
Compose message
Distress acknowledge call in progress
Distress alert received on HF band
Sending the distress relay to coast station on HF band
Action for ships receiving distress alert on HF band
Compose message
Push the Enter knob to open the DSC FREQ. menu
Distress relay sel call in progress
Category distress transmit sure?
Sending distress relay to coast station
Sending Distress Relay on Behalf of a Ship in Distress
Push the Enter knob to open the Nature menu Compose message
ID in Dist No Info Nature Sinking
Communicate with the coast station
Sending distress relay to all ships
Ship in distress and time, manually or automatically
Push the Enter knob to open the Nature menu
Distress relay all call in progress
Receiving Distress Relay from Coast Station
Receiving Distress Relay All Ships
This page intentionally left blank
Sending an all ships call
CALLING, Receiving
All Ships Call
CALLING, Receiving
Sending message by Nbdp Terminal Unit
Receiving an all ships call
Sending an individual call
Individual Call
NBDP-ARQ
Routine or ships business priority
How to Set Working Frequency, Channel
How to Set DSC Frequency
Press Call key for forced transmission
No response! Try calling again?
Able acknowledge call received
Unable acknowledge call received
Can send acknowledge Can send Unable Automatically
Setting ACQ /SQ key
Sending automatic acknowledge ACK BQ with comply type Unable
Manually acknowledging individual call with Able
Call Type Able Acknowledgement
Manually acknowledging individual call with Unable
Display changes as below Compose message
Group Call
Sending a group call
MHZ
Priority Routine COM. Type Telephone COM. Freq
Receiving message by Nbdp Terminal Unit
Receiving a group call
Sending a geographical area call
Geographical Area Call
↓ 10 →
Area 34 N 140 W ↓ 10 →
Receiving a geographical area call
Sending a neutral craft call
Neutral Craft Call
Sending message by Nbdp Terminal Unit
Receiving a neutral craft call
Sending a medical transport call
Medical Transport Call
Receiving a medical transport call
Sending a polling call
Polling Call
Call Type Station ID
Polling acknowledge call received
Automatic reply
Receiving a polling call
After the call is sent the DSC standby screen appears
Manual reply
Sending own ships position to other station
Position Call
Finding position of other station
Position call requesting other ship’s position
Pos acknowledge call received
Automatic reply
Position call other ship requests your position
Acknowledge call received
Manual reply
Sending a Pstn call, receiving acknowledge back ACK BQ
Pstn Call
Push the Enter knob to open the TEL NO. menu Compose message
Then, one of the following displays appears
Waiting for acknowledgement
Unable acknowledge call received
Receiving a Pstn call, sending acknowledge back ACK BQ
Shortly thereafter, one of the following messages appears
Charge Information Charge Time 00H 12M 34S
Opening a log file
To view the contents of a file, do the following
Log File
Erasing Message Files
Preparing Individual Calls
Preparing TX Calls
NBDP-FEC COM. Freq No Info DSC Freq
Enter file name and number as shown on the next
How to Enter File Name and Number
Preparing Group Calls
Preparing Geographical Area Calls
Call Type GROUP6CALL
Preparing Pstn Calls
Preparing Test Calls
Editing before sending
Sending Prepared Calls
Sending without modification
Printing List of Send Message Files
Deleting Send Message Files
Setting Alarms
DSC/WATCH Receiver Setup
Can send acknowledge Can send Unable manually Manually
Auto Ack Menu
Sample printouts
Printing Messages
Routine frequencies
Setting Scan Frequencies
Distress frequencies
Local channels
International channels
Distress channels
Volume setup
Adjusting Volume
Nbdp terminal unit, printer and keyboard
Nbdp System Overview
Turning on the Nbdp System
Communication status display
Features of the IB-583
Description of Equipment
Terminal unit
Keyboard
Keyboard
Underline
Function Keys, Menu Operation
Menu conventions
Inverse video
Selecting menu items and options
Menu overview
Selecting menus
File menu
Function key description
Copy
Edit menu
Undo
Cut
Call Station
Cancel Sending
Timer Operation
Function key F3 Operate menu
Displays desired calendar month and year. To change
Setting with ← or → key
Function key F4 Window menu
Window menu
Select ID Entry
Function key F5 Station menu
Group ID Entry
TX/RX MSG Save
Setup
Slave Delay
Function key F6 System menu
Cursor is choosing Window Color Setup press the Enter key
Answerback code entry screen
Nbdp Preparations
Registering Answerback Code & ID Codes
Registering answerback code
ID code screen
Station List
Registering ID codes
Message for confirmation of code entered
Station entry screen
Registering stations
Scanning group list
OK/Cancel prompt
Editing/Deleting stations
Timer operation entry screen
Timer Programming
Registering timer programs
User channel entry screen
Editing/Deleting timer programs
To quit, press the Esc key
Scan Channel Groups
Editing/Deleting user channels
Registering scan channel groups
Deleting channels
Editing/Deleting scan channel groups
Editing channels
Adding channels
10-1
Nbdp File Operations
Opening and Closing Files
Creating Files
Type your message
10-2
10-3
Saving a File
Formatting floppy disks
Close text screen
Saving a file
10-4
Cutting text
Editing Files
Cutting and pasting text
10-5
10-6
Copying and pasting text
Select all
Searching text
Replace screen
Replacing text
Goto line
10-7
Opening a file
Switching between files
Opening Files
Goto top, Goto bottom
Real Time Printing
Renaming Files
Saving a File Under a New Name
Deleting Files
10-10
Printing Files
Press the 9 key to choose Set Frequency
Nbdp TRANSMITTING, Receiving
Manual Calling
11-1
Manual calling screen
11-2
Press the 1 key to choose Call Station
ARQ Mode Operation
11-3
Establishing connection
Send file screen
11-4
Transmit message by one of the following methods
Sending a file stored on a floppy disk
Stopping transmission
FEC Mode Operation
Choosing Receive Mode
11-5
Communications example
Communication Example
11-6
Table of abbreviations
11-7
Timer operation list
Timer Operation
Enabling timer operation
Command and abbreviation
11-9
Stopping timer operation
Scanning
11-10
Communication Buffer
Preparing Macrofiles for Automatic Telex
Automatic telex overview
Registering scan groups
Preparations
11-11
Registering answerback code
Command Function
Commands
Command Parameter Content
Commands processed by Danish coast station Lyngby
11-13
Actual procedure for store-and-forward telex
Store-and-forward method
Close text prompt
11-14
Sample macrofile for store-and-forward method
Sample Dirtlx macrofile
Dirtlx macrofile
11-15
Press the Enter key and enter a file name as follows
11-16
Procedure for Dirtlx
11-17
Automatic Telex using Macrofile
Basic procedure
Actual procedure
Press the ↓ key to choose a macrofile Press the Enter key
11-18
Call macro screen
12-1
Maintenance & Troubleshooting
Daily Test
12-2
Radiotelephone Test
Antenna Coupler Test
Check Point Remedy/Remarks
Maintenance
Maintenance check points
12-3
Unit Fuse
Replacement of Fuses
12-4
Error message Meaning Remedy
Simple Troubleshooting
Error Messages
Problem Probable cause Remedy
WR1, WR2 PLL unlock Check if the reference oscillator is
12-6
12-7
Test Call
12-8
Floppy disk drive
Nbdp Terminal Unit Maintenance
Cleaning the equipment
Connectors and earth connection
Press the function key F6 to display the System menu
Diagnostics
General diagnostics
12-10
Tone test
12-11
Tone test
Tone test menu
12-12
AP-1
Appendix
Menu Tree
DSC/watch receiver
AP-2
Radiotelephone
AP-3
Nbdp terminal unit telex
TX kHz RX kHz Remarks File Name
Frequency Tables
DSC frequency table
AP-4
AP-5
Custom channels to be programmed by Furuno dealers
AP-6
MF band working carrier frequencies ref. US CFR 47 Part
AP-7
MF band SSB working carrier frequencies
AP-8
MHz ITU SSB carrier frequencies ITU RR Appendix
AP-9
AP-10
12/16 ITU SSB carrier frequencies ITU RR Appendix
AP-11
18/19, 22, 25/26 ITU SSB carrier frequencies ITU RR Appendix
AP-12
MF band telex frequency table
ITU Telex frequency /4
AP-13
Frequency /4
AP-14
AP-15
ITU Telex Frequency /4
AP-16
AP-17
Telex Abbreviations
Input sentences IEC
Digital Interface IEC
O Sentences
AP-18
ZDA Time and date
AP-19
GLL Geographic position latitude/longitude
RMA Recommended minimum specific LORAN-C data
AP-20
RMC Recommended minimum specific GPS/TRANSIT data
AP-21
AP-22
Schematic diagram
Model FS-1570/2570 Unit
Parts List
AP-23
Control unit FS-1570/2570
Model FS-1570T Unit
AP-24
Transceiver unit FS-1570T
Model FS-2570T Unit
AP-25
Transceiver unit FS-2570T
AP-26
Parts Location
Transceiver unit FS-2570T
AP-27
Transceiver unit FS-1570T
AP-28
Control unit FS-2570C
IN-1
Index
Index
IN-2