Locate the antenna above the radar antenna, out of the radar beam.

Sc-series Antenna

Radar Antenna

Example of improper installation

Location influenced by reflected wave.

NO! UNSUITABLE LOCATION SC-series

SC-series antenna located Antenna below all other structures

RadarAntenna

Reception blocked by mast.

Bridge

Example of improper installation

2.1.2Display unit, processor unit

Choose a location where vibration and shock are minimal.

Install the units well away from locations subject to rain and water splash.

Locate the units well away from air conditioner vents.

Keep the units out of direct sunlight because of heat that can build up inside their cabinets.

Choose a well-ventilated location.

For the display unit, choose a location where it can be easily operated.

Leave sufficient space around the units to permit access for maintenance. See the outline drawing for recommended maintenance space.