2. INSTALLATION

Note: When switching from internal heading to external heading when using an autopilot in the auto mode, set the autopilot in the manual mode BEFORE switching, adjust heading at the autopilot and then switch to the auto mode.

5.Press the [ENT] key.

6.Press the [DISP] key to close the menu.

2.6.3Heading data format

1.Turn off the processor unit.

2.Unfasten four screws from the processor unit to remove the top cover.

3.Choose the heading format of the equipment connected to the ports HDG OUT 1, HDG OUT 2 and HDG OUT 3 with the jumper wires on the circuit board 20P8171, referring to the table below. The default setting for each port is AD-10.

Jumper wire and format on the circuit board 20P8171

Port

Format

 

Setting

 

Remarks

HDG OUT

AD-10

 

J11 < - > J13

 

NMEA and AD-10 are identified

1

NMEA

 

J11 < - > J12

 

on the circuit board. Choose

 

 

 

 

 

NMEA for IEC 61162-1

HDG OUT

AD-10

 

J14 < - > J16

 

2

 

 

 

 

sentences.

NMEA

 

J14 < - > J15

 

HDG OUT

AD-10

 

J17 < - > J19

 

 

3

NMEA

 

J 17 < - > J18

 

 

 

 

 

 

NMEA

 

 

 

 

(IEC 61162)

ANGULAR

HEAD1

 

AD-10

RATE SENSOR

 

 

 

BEACON

20P8171

NMEA (IEC 61162)

 

HEAD2

 

AD-10

HEAD3

AD-10

NMEA (IEC 61162)

Processor unit, cover opened, top view

2-21